產品介紹實驗室儀器設備自動細胞計數儀Cellometer Auto T4 明視野自動細胞計數儀 (Cellometer Auto T4 Bright Field Cell Counter)

Cellometer Auto T4 明視野自動細胞計數儀

Cellometer Auto T4 明視野自動細胞計數儀 (Cellometer Auto T4 Bright Field Cell Counter) - Nexcelom Bioscience (part of PerkinElmer) 台灣代理伯森生技

歡迎與我們聯繫索取更多 Cellometer Auto T4 產品資訊與文獻。

產品效能

Fig. 1 | Simple Cell Counting & Trypan Blue Viability in Seconds! Within 30 seconds, the Auto T4 instrument reports: • Live, dead, and total cell count • Live and total cell concentration • Mean Cell Diameter • % Viability.

 

Fig. 2 | Analyze >99% of Cultured Mammalian Cells, including NCI-60 and clumpy MCF-7 cells. (A) The Cellometer cell roundness setting can be adjusted for recognition and counting of irregular-shaped cells, such as RD cells and activated T-cells. (B) The MCF-7 breast cancer cell line can be very clumpy. The Cellometer pattern-recognition software identifies and counts individual cells within these cell clumps for accurate analysis.

 

Fig. 3 | The Auto T4 Cell Counter Automatically generates a cell size histogram based on cell diameter. ecause Cellometer generates individual cell size measurements, multiple samples can be overlaid on one histogram enabling analysis of the change in cell diameter over time.

 

Fig. 4 | Multiple Cell Images for Data Verification. With the Auto T4 Cell Counter, cell morphology can be immediately viewed on-screen. Two images with four fields of view each are captured per cell count. This is equivalent to the area of four quadrants of a hemocytometer. Users can confirm that: (1) Cells are counted correctly, based on size and shape, (2) Debris is excluded, (3) Cells within clumps are being counted individually, (4) Cell images can be archived and exported for use in publications and presentations, (5) Saved images can be re-counted using default or user-optimized analysis settings.

 

Fig. 5 | Exclusion of Debris. Because Cellometer recognizes cells based on size, brightness, and morphology, cellular debris is easily and accurately excluded from counting results.

 

Fig. 6 | 10x Faster and More Precise than Manual Counting. Counting 1 x 10⁶ cells takes approximately 5 minutes with a manual hemacytometer. Counting live and dead cells sometimes takes twice as long. The Cellometer Auto T4 Cell Counter calculates cell count and concentration for live and dead cells and % viability in just 10 seconds. The Cellometer %CV (Coefficient of Variation), including sample preparation, was well under 5% for most cell lines tested. The CVs for manual counts ranged from 7% to 20%. Automated cell counters remove inter-operator variability and subjectivity from cell counts to generate more precise data.

產品規格

Cellometer Auto T4 Includes
  • Cellometer Auto T4 Instrument
  • Cellometer Software
  • USB 2.0 Connection Cable
  • Power Supply
  • Support during set-up
Available Accessories PC laptop
Channels Brightfield
Number of Channels 1
Counting Speed Per Sample <30 sec
Volume (per chamber) 20 µl
Cell Size/Diameter Range 5–60 µm (most mammalian cells)
Concentration Range 10⁵ – 10⁷ cells/ml
Software Cellometer Auto Pattern-recognition software to quickly and accurately decluster, identify and count individual cells
Weight 4.7 kg
Dimensions W8.9 x D10.7 x H32.0 cm
Power Adapter Input 100–240 VAC, 50/60 Hz, 0.5A; Output: 12 VDC, 1.5A
PC / Laptop Requirements
(If purchasing Cellometer without PC laptop)
  • Windows 7, 8 or 10
  • 1.6 GHz or higher processor
  • 2 GB RAM
  • USB 2.0 port
  • Display resolution: 1024 x 768 pixels or higher
Intel Mac with Parallels/Windows

訂購資訊

Product Name Cat. No.
Cellometer Auto T4 Bright Field Cell Counter Cellometer-Auto-T4
產品文件與相關資源